Range Of Product | |
---|---|
Product Or Component Type | |
Product Destination | |
Product Specific Application | |
Component Name | |
Network Number Of Phases | |
[Us] Rated Supply Voltage | |
Motor Power kW | |
Factory Setting Current | |
Power Dissipation In W | |
Utilisation Category | |
Type Of Start | |
Icl Starter Rating | 47 A connection in the motor supply line for standard applications |
IP Degree Of Protection | |
Assembly Style | |
Function Available | |
Supply Voltage Limits | |
Supply Frequency | |
Network Frequency | |
Device Connection | |
Uc Control Circuit Voltage | |
Control Circuit Consumption | |
Discrete Output Number | |
Discrete Output Type | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O, Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O |
Minimum Switching Current | |
Maximum Switching Current | 2 A 250 V AC inductive 0.4 20 ms relay outputs, 2 A 30 V DC inductive 7 ms relay outputs, 5 A 250 V AC resistive 1 relay outputs, 5 A 30 V DC resistive 1 relay outputs |
Discrete Input Number | |
Discrete Input Type | |
Discrete Input Voltage | |
Discrete Input Logic | |
Output Current | |
PTC Probe Input | |
Communication Port Protocol | |
Connector Type | |
Communication Data Link | |
Physical Interface | |
Transmission Rate | |
Installed Device | |
Protection Type | Phase failure line, Thermal protection motor, Thermal protection starter |
Marking | |
Type Of Cooling | |
Operating Position | |
Height | |
Width | |
Depth | |
Product Weight | |
Motor Power Range Ac-3 | 15 25 kW 380 440 V 3 phase, 30 50 kW 480 500 V 3 phase, 7 11 kW 200 240 V 3 phase |
Motor Starter Type | |
Electromagnetic Compatibility | Conducted and radiated emissions level A IEC 60947-4-2, Damped oscillating waves level 3 IEC 61000-4-12, Electrostatic discharge level 3 IEC 61000-4-2, Immunity to electrical transients level 4 IEC 61000-4-4, Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3, Voltage/current impulse level 3 IEC 61000-4-5 |
Standards |
Schneider Electric ATS22D47S6
Soft starter-ATS22-control 220V-power 230V(11kW)/400…440V(22kW)/500V(30kW)
This Altistart 22 soft starter can feed 3-phase asynchronous motors in supply line connection. It has a rating of 47A, a rated power from 11kW to 30kW and a rated voltage from 230V to 500V AC. It is designed for simple and complex machines such as centrifugal and piston pumps, fans, screw compressors and material handling equipment. Slim form factor improves versatility; allows mounting in frames of any kind of machines. It features an Integrated bypass, this reduces noise and decreases heat dissipation. Compatibility with SoMove software allows configurations and settings to be easily transferred, meaning spares can be quickly installed. It provides smooth starting for your machinery, avoiding mechanical stresses and extending their service life.
Brand
Schneider Electric